MNS-4H2S-100 Electrochemical H2S Gas Sensor 0-100 ppm

Product Description

Description

This H2S gas sensor uses three-electrode electrochemical sensing technology for hydrogen sulfide concentration measurement. It provides a linear signal output with fast response, good repeatability and stable performance. The compact structure makes it suitable for integration into portable, fixed and OEM hydrogen sulfide detection equipment.

Features

  • Three-electrode electrochemical sensing technology for reliable H2S detection

  • Fast response for timely hydrogen sulfide concentration monitoring

  • Good repeatability with stable and linear signal output

  • Wide environmental adaptability for industrial gas detection applications

  • Low cross-sensitivity to NO, NH3, CO2 and ethylene under specified test conditions

Application

  • Hydrogen sulfide gas detectors

  • Portable and fixed gas detection equipment

  • Industrial safety monitoring systems

  • Wastewater and sewage monitoring equipment

  • Oil, gas and petrochemical monitoring equipment

  • OEM H2S sensing equipment

Specifications

Detection Principle

Electrochemical

Measurement Range

0–100 ppm

Maximum Overload

200 ppm

Sensitivity

0.7 ± 0.25 μA/ppm

Resolution

1 ppm

Response Time

<30 s

Bias Voltage

0 mV

Output Characteristic

Linear

Repeatability

<±2%

Long-term Stability

<15% Signal Value/Year

Operating Temperature

-20°C to +50°C

Operating Pressure

800–1200 mbar

Operating Humidity

15%–90% RH

Storage Temperature

0°C to +20°C

Service Life

2 Years

Warranty Period

1 Year

Maximum Open-circuit Voltage

1.3 V

Maximum Short-circuit Current

<1.0 A

Maximum Current at 2000 ppm

0.3 mA

Recommended Load Resistor

10 Ω

FAQs

What gas does the MNS-4H2S-100 detect?

The MNS-4H2S-100 is designed to detect hydrogen sulfide, commonly abbreviated as H2S.

What type of gas sensor is the MNS-4H2S-100?

It is a three-electrode electrochemical hydrogen sulfide sensor.

What is the H2S measurement range?

The specified measurement range is 0-100 ppm.

What is the maximum overload?

The specified maximum overload is 200 ppm H2S.

What is the sensitivity of the sensor?

The nominal sensitivity is 0.7 ± 0.25 μA/ppm.

What is the resolution?

The specified resolution is 1 ppm.

What is the response time?

The response time is less than 30 seconds.

Does the sensor require a bias voltage?

The specified bias voltage is 0 mV.

What is the operating temperature range?

The MNS-4H2S-100 operates from -20°C to +50°C.

What is the operating humidity range?

The specified humidity range is 15%-90% RH.

What is the expected service life?

The specified service life is approximately 2 years under suitable storage and operating conditions.

Is the MNS-4H2S-100 suitable for portable gas detectors?

Yes. Its compact Ø20 mm design, electrochemical sensing principle and fast response make it suitable for portable H2S detectors and multi-gas instruments.

Can the MNS-4H2S-100 be used in OEM products?

Yes. It is designed for integration into OEM hydrogen sulfide detectors, industrial safety instruments, environmental monitoring systems and other gas detection equipment.

Product Inquiry

MNS-4CL2-10 Electrochemical Chlorine Cl2 Gas Sensor 0-10 ppm

MNS-4CO-1000 Electrochemical Carbon Monoxide CO Gas Sensor 0-1000 ppm

MNS-4O3-10 Electrochemical Ozone O3 Gas Sensor 0-10 ppm

MNS-QT221 NDIR CO2 Gas Sensor

NDIR Methane CH4 Gas Sensor 0-100%LEL with UART Output