MNS-4NO2-20 Electrochemical Nitrogen Dioxide NO2 Gas Sensor

Product Description

MNS-4NO2-20 Electrochemical Nitrogen Dioxide Gas Sensor

The MANORSHI MNS-4NO2-20 is an electrochemical gas sensor designed for nitrogen dioxide (NO2) detection.

The target gas undergoes oxidation-reduction reactions at the working electrode and counter electrode, releasing electric charges and generating a current through the external circuit. The generated current is proportional to the gas concentration, enabling quantitative measurement of nitrogen dioxide. MNS-4NO2-20 Nitrogen Dioxide ga…

Key Features

  • High stability

  • Quick response and recovery

  • Strong adaptability to the environment

Technical Specifications

Parameter

Specification

Product Model

MNS-4NO2-20

Target Gas

Nitrogen Dioxide (NO2)

Detection Principle

Electrochemical

Measuring Range

0–20 ppm

Maximum Load

250 ppm

Sensitivity

0.60 ± 0.15 μA/ppm

Response Time

≤30 s

Resolution

0.1 ppm

Bias Voltage

0 mV

Linearity

Linear

Long-Term Stability

<2% Signal Value/Month

Temperature Range

-20°C to +50°C

Pressure Range

800–1200 mbar

Humidity Range

15%–95% RH, Non-condensing

Storage Temperature

0°C to +20°C

Service Life

2 Years

Warranty Period

1 Year

Maximum O/C Voltage

1.3 V

Maximum S/C Current

<1.0 A

Maximum Current at 250 ppm

<0.2 mA

Cross-Interference

Interfering Gas

Concentration

Output Signal

CO

300 ppm

-1 ppm

H2S

15 ppm

-1 ppm

SO2

5 ppm

-5 ppm

CL2

1 ppm

-1 ppm

NO

35 ppm

0.0 ppm

Application Circuit

The supplied datasheet also includes a recommended application circuit for connecting and conditioning the electrochemical sensor signal.

Applications

  • Industrial NO2 gas detection

  • Environmental NO2 monitoring

  • Gas detection instruments

  • Industrial environmental monitoring equipment

FAQs

What gas does the MNS-4NO2-20 detect?

The sensor is designed for nitrogen dioxide (NO2) detection.

What is the measuring range?

The specified measuring range is 0–20 ppm.

What is the maximum load?

The specified maximum load is 250 ppm.

What is the sensitivity?

The specified sensitivity is 0.60 ± 0.15 μA/ppm.

What is the response time?

The specified response time is ≤30 seconds.

What is the resolution?

The specified resolution is 0.1 ppm.

Does the sensor require bias voltage?

The specified bias voltage is 0 mV.

What is the operating temperature range?

The specified temperature range is -20°C to +50°C.

What is the expected service life?

The specified service life is 2 years.

What applications is it suitable for?

The datasheet specifies NO2 detection in industrial and environmental monitoring applications.

Product Inquiry

MNS-4SO2-20 Electrochemical Sulfur Dioxide SO2 Gas Sensor

MNS-4NO-250 Electrochemical Nitric Oxide NO Gas Sensor

MNS-4NH3-100 Electrochemical Ammonia NH3 Gas Sensor

MNS-4CL2-10 Electrochemical Chlorine Cl2 Gas Sensor 0-10 ppm