MNS-4H2S-100 Electrochemical H2S Gas Sensor 0-100 ppm

Product Description

Key Features

  • Target gas: Hydrogen Sulfide (H2S)

  • Electrochemical gas sensing technology

  • Linear output characteristics

  • Three-electrode configuration

  • Service life: approximately 2 years

  • Suitable for portable, fixed and OEM gas detectors

Technical Specifications

Product Model: MNS-4H2S-100

Brand: MANORSHI

Target Gas: Hydrogen Sulfide / H2S

Detection Principle: Electrochemical

Measurement Range: 0-100 ppm

Maximum Overload: 200 ppm

Sensitivity: 0.7 ± 0.25 μA/ppm

Resolution: 1 ppm

Response Time: <30 s

Bias Voltage: 0 mV

Output Characteristic: Linear

Repeatability: <±2%

Long-Term Stability: <15% signal value/year

Operating Temperature: -20°C to +50°C

Operating Pressure: 800-1200 mbar

Operating Humidity: 15%-90% RH

Recommended Storage Temperature: 0°C to +20°C

Service Life: Approximately 2 years

Warranty Period: 1 year

Maximum Open-Circuit Voltage: 1.3 V

Maximum Short-Circuit Current: <1.0 A

Recommended Load Resistor: 10 Ω

What Is the MNS-4H2S-100 H2S Sensor?

The MNS-4H2S-100 is an electrochemical gas sensor specifically designed to detect hydrogen sulfide, commonly identified by the chemical formula H2S.

Hydrogen sulfide is a toxic gas that may be present in wastewater treatment, oil and gas facilities, chemical processing plants, mining operations, sewers and other industrial environments.

The MNS-4H2S-100 converts the electrochemical reaction caused by H2S into an electrical current. The output signal changes according to the hydrogen sulfide concentration and can be processed by an external signal conditioning circuit to obtain a gas concentration reading.

How Does an Electrochemical H2S Sensor Work?

The MNS-4H2S-100 uses a three-electrode electrochemical sensing structure consisting of a working electrode, reference electrode and counter electrode.

When hydrogen sulfide reaches the sensing area, H2S molecules diffuse through the gas-permeable membrane and react at the working electrode.

This reaction generates an electrical current related to the H2S concentration. The reference electrode helps maintain a stable electrode potential, while the counter electrode completes the electrochemical reaction.

The generated current is then amplified and processed by the external electronic circuit to calculate the hydrogen sulfide concentration.

This electrochemical sensing principle provides high sensitivity, compact size and low power requirements, making it suitable for portable and fixed H2S gas detectors.

MNS-4H2S-100 Electrochemical H2S Gas Sensor

The MANORSHI MNS-4H2S-100 is a compact electrochemical hydrogen sulfide gas sensor designed for reliable H2S concentration measurement in portable gas detectors, fixed gas monitoring systems, industrial safety equipment and OEM gas detection products.

The sensor provides a 0-100 ppm H2S measurement range with a maximum overload of 200 ppm. With a response time of less than 30 seconds, 1 ppm resolution and 0.7 ± 0.25 μA/ppm sensitivity, the MNS-4H2S-100 is suitable for continuous hydrogen sulfide monitoring in industrial and environmental applications.

Its compact Ø20 mm package and three-electrode electrochemical structure make it suitable for integration into space-limited gas detection instruments.

Typical Applications

The MNS-4H2S-100 electrochemical hydrogen sulfide sensor can be used in a wide range of H2S detection applications, including:

  • Portable H2S gas detectors

  • Fixed hydrogen sulfide detectors

  • Multi-gas safety detectors

  • Industrial gas monitoring systems

  • Oil and gas safety equipment

  • Petrochemical facilities

  • Wastewater treatment plants

  • Sewer gas monitoring

  • Biogas monitoring systems

  • Mining safety equipment

  • Chemical processing facilities

  • Confined space gas detectors

  • Environmental monitoring instruments

  • Occupational safety equipment

  • OEM gas sensing products

H2S Detection for Industrial Safety

Hydrogen sulfide may be generated or released in oil and gas production, petroleum processing, wastewater treatment, mining, chemical manufacturing and other industrial processes.

Because H2S is toxic, industrial facilities often use gas detection equipment to monitor areas where hydrogen sulfide may accumulate.

The MNS-4H2S-100 provides a compact sensing element for manufacturers developing H2S monitors, fixed gas detectors and portable safety instruments.

Its 0-100 ppm measurement range and <30 second response time make it suitable for continuous hydrogen sulfide monitoring applications.

Why Choose the MANORSHI MNS-4H2S-100?

The MANORSHI MNS-4H2S-100 combines electrochemical H2S detection, fast response, compact dimensions and a three-electrode structure in one gas sensor.

Its 0-100 ppm range is suitable for many industrial hydrogen sulfide monitoring applications, while the <30 second response time supports rapid detection of changing H2S concentrations.

For OEM manufacturers, the compact Ø20 mm package provides a practical solution for integration into portable detectors, fixed gas monitoring equipment and multi-gas safety instruments.

Frequently Asked Questions

What gas does the MNS-4H2S-100 detect?

The MNS-4H2S-100 is designed to detect hydrogen sulfide, commonly abbreviated as H2S.

What type of gas sensor is the MNS-4H2S-100?

It is a three-electrode electrochemical hydrogen sulfide sensor.

What is the H2S measurement range?

The specified measurement range is 0-100 ppm.

What is the maximum overload?

The specified maximum overload is 200 ppm H2S.

What is the sensitivity of the sensor?

The nominal sensitivity is 0.7 ± 0.25 μA/ppm.

What is the resolution?

The specified resolution is 1 ppm.

What is the response time?

The response time is less than 30 seconds.

Does the sensor require a bias voltage?

The specified bias voltage is 0 mV.

What is the operating temperature range?

The MNS-4H2S-100 operates from -20°C to +50°C.

What is the operating humidity range?

The specified humidity range is 15%-90% RH.

What is the expected service life?

The specified service life is approximately 2 years under suitable storage and operating conditions.

Is the MNS-4H2S-100 suitable for portable gas detectors?

Yes. Its compact Ø20 mm design, electrochemical sensing principle and fast response make it suitable for portable H2S detectors and multi-gas instruments.

Can the MNS-4H2S-100 be used in OEM products?

Yes. It is designed for integration into OEM hydrogen sulfide detectors, industrial safety instruments, environmental monitoring systems and other gas detection equipment.

Product Inquiry

MNS-4CL2-10 Electrochemical Chlorine Cl2 Gas Sensor 0-10 ppm

MNS-4CO-1000 Electrochemical Carbon Monoxide CO Gas Sensor 0-1000 ppm

MNS-4O3-10 Electrochemical Ozone O3 Gas Sensor 0-10 ppm

MNS-QT221 NDIR CO2 Gas Sensor

NDIR Methane CH4 Gas Sensor 0-100%LEL with UART Output