| Image | Product Name | Model | Dimension | Rated Voltage | Frequency | SPL | Current | Operating Voltage | Details |
|---|---|---|---|---|---|---|---|---|---|
![]() | MNS-QT221 NDIR CO2 Gas Sensor | MNS-QT221 | 14*16mm | <85mA | 3.3~5V | View detail » | |||
![]() | NDIR Methane CH4 Gas Sensor 0-100%LEL with UART Output | MNS-QT331 | 14*16mm | <85mA | 3.3~5V | View detail » |
MANORSHI is a manufacturer and supplier of NDIR infrared gas sensors for carbon dioxide (CO2) and methane (CH4) detection. Our infrared gas sensor range includes the MNS-QT221 NDIR CO2 sensor and MNS-QT331 NDIR methane sensor, designed for integration into industrial gas detection equipment, indoor air quality monitoring systems, HVAC controllers and OEM electronic instruments.
Non-Dispersive Infrared (NDIR) technology measures gas concentration by analyzing the absorption of infrared light at specific wavelengths. Compared with electrochemical sensing, NDIR technology does not rely on a chemical reaction at an electrode and is suitable for monitoring infrared-absorbing gases such as carbon dioxide and methane.
MANORSHI NDIR gas sensors feature compact 14 × 16mm dimensions, 3.3–5V DC operating voltage and response times of less than 30 seconds. The CO2 model supports UART digital communication and 0.4–2V analog output, while the methane model provides UART communication for electronic system integration.
Whether you manufacture gas detectors, HVAC equipment, indoor air quality monitors, industrial safety instruments or environmental monitoring devices, MANORSHI provides infrared gas sensing components for OEM product development and bulk purchasing.
Request a QuoteRequest Samples
NDIR gas sensors use the infrared absorption characteristics of specific gas molecules to measure their concentration. Different gases absorb infrared radiation at characteristic wavelengths, allowing an optical sensing system to identify and quantify a target gas.
A typical NDIR gas sensor contains an infrared light source, a gas chamber, an optical filter and an infrared detector. When infrared light passes through the gas chamber, target gas molecules absorb part of the radiation at the selected wavelength. The detector measures the remaining infrared energy, and the electronic circuit calculates the gas concentration from the absorption signal.
The basic measurement process includes the following steps:
Infrared Emission: An infrared source generates radiation at selected wavelengths.
Gas Absorption: Target gas molecules absorb infrared energy according to their characteristic absorption bands.
Optical Detection: An infrared detector measures the radiation remaining after it passes through the gas sample.
Signal Processing: Electronic circuitry analyzes the optical signal and calculates the gas concentration.
Output Transmission: The measured concentration is provided to the connected controller through a digital or analog interface.
Because NDIR sensors use an optical measurement principle rather than an electrochemical reaction, they do not depend on a consumable sensing electrode. Their actual service life and measurement stability still depend on the infrared source, optical components, electronic design, calibration and operating environment.
The MNS-QT221 is designed for CO2 measurement, while the MNS-QT331 is designed for methane detection. Each model uses an appropriate optical configuration and calibration for its specified target gas.
MANORSHI currently offers two NDIR infrared gas sensor models for carbon dioxide and methane measurement. Both models feature compact dimensions and are designed for integration into electronic gas monitoring equipment.
Specification | MNS-QT221 | MNS-QT331 |
|---|---|---|
Target Gas | Carbon Dioxide (CO2) | Methane (CH4) |
Detection Principle | NDIR | NDIR |
Dimensions | 14 × 16mm | 14 × 16mm |
Measurement Range | 0–2000 ppm, 0–5000 ppm, 0–1%, 0–2%, 0–5%, 0–100% VOL | 0–100% LEL, 0–5% VOL, 0–100% VOL |
Accuracy | ±5% FS | ±5% FS |
Operating Voltage | 3.3–5V DC | 3.3–5V DC |
Average Current | <85mA | <85mA |
Output Signal | UART / 0.4–2V | UART |
Response Time | T90 <30s | T90 <30s |
Operating Temperature | -20°C to +60°C | Confirm according to the selected product datasheet |
Measurement ranges are available as different configurations and should be confirmed when ordering. Accuracy, response time and electrical specifications are based on the published model data. Please request the latest datasheet to confirm the exact configuration required for your project.
The MNS-QT221 is a compact NDIR carbon dioxide sensor designed to measure CO2 concentrations in indoor air quality monitoring equipment, HVAC systems, industrial monitoring instruments and environmental measurement devices.
Using infrared absorption technology, the MNS-QT221 measures carbon dioxide concentration without relying on an electrochemical reaction. Its multiple measurement range options allow equipment manufacturers to select a suitable configuration for different CO2 monitoring requirements.
The MNS-QT221 supports different measurement range configurations, including:
0–2000 ppm for indoor air quality monitoring.
0–5000 ppm for higher CO2 concentration monitoring.
0–1% VOL and 0–2% VOL for industrial and process monitoring.
0–5% VOL for higher-concentration CO2 measurement.
0–100% VOL for high-concentration carbon dioxide applications.
The selected measurement range should match the expected CO2 concentration and the operating requirements of the complete monitoring instrument.
The MNS-QT221 supports UART digital communication and 0.4–2V analog voltage output. These interfaces allow the sensor to be integrated into embedded controllers, gas detectors, ventilation controllers and environmental monitoring systems.
The sensor operates from a 3.3–5V DC power supply and has an average current consumption of less than 85mA. Its specified warm-up time is 180 seconds, and its response time is T90 less than 30 seconds.
NDIR infrared absorption detection principle.
Multiple selectable CO2 measurement ranges.
UART and 0.4–2V analog output.
Temperature compensation.
Resistance to water vapor interference.
Operating temperature from -20°C to +60°C.
Operating humidity from 0–95% RH, non-condensing.
IP65 protection level.
Expected service life exceeding five years under suitable operating conditions.
For detailed pin assignments, electrical specifications and measurement range selection, please refer to the MNS-QT221 product datasheet.
The MNS-QT331 is an NDIR methane gas sensor designed for CH4 concentration measurement in combustible gas detection equipment, natural gas monitoring systems and industrial gas safety instruments.
Methane absorbs infrared radiation at characteristic wavelengths. The MNS-QT331 uses this optical absorption principle to measure methane concentration and provide digital output to the connected electronic control system.
The MNS-QT331 product range includes the following measurement configurations:
0–100% LEL: For combustible gas concentration monitoring expressed as a percentage of the lower explosive limit.
0–5% VOL: For methane volume concentration measurement in lower concentration ranges.
0–100% VOL: For high-concentration methane measurement.
The required measuring range should be confirmed according to the intended gas detector design, calibration gas and alarm requirements. Different measurement ranges should not be treated as interchangeable configurations.
The MNS-QT331 provides UART digital communication for integration into gas monitoring controllers, combustible gas detectors and embedded electronic systems. Its 3.3–5V DC operating voltage supports integration into different low-voltage electronic equipment designs.
The product listing specifies an average current consumption of less than 85mA and a response time of T90 less than 30 seconds. Its compact 14 × 16mm dimensions make it suitable for equipment designs with limited installation space.
NDIR methane detection technology.
Designed for CH4 concentration measurement.
Measurement options from 0–100% LEL to high-concentration VOL ranges.
UART digital communication.
3.3–5V DC operating voltage.
Average current consumption below 85mA.
T90 response time below 30 seconds.
Compact 14 × 16mm product dimensions.
For natural gas and combustible gas detector manufacturers, the selected measurement range, calibration method and instrument alarm thresholds should be evaluated together during product development.
NDIR gas sensors are used in industrial, commercial and environmental monitoring equipment where infrared-absorbing gases need to be measured. The MNS-QT221 and MNS-QT331 support different application requirements according to their respective target gases and measurement ranges.
NDIR CO2 sensors are commonly integrated into indoor air quality monitoring equipment to measure carbon dioxide concentration in offices, commercial buildings, schools, meeting rooms and public facilities. CO2 measurement can provide information for ventilation management and indoor environmental monitoring.
The MNS-QT221 supports selectable measurement ranges for different indoor and industrial CO2 monitoring requirements.
HVAC equipment manufacturers use CO2 sensing components in demand-controlled ventilation systems. The measured carbon dioxide concentration can be transmitted to a ventilation controller, which adjusts fresh air supply according to the system's control strategy.
The MNS-QT221's UART and analog voltage outputs provide interface options for HVAC controllers and embedded ventilation monitoring equipment.
Carbon dioxide concentration is an important parameter in greenhouse cultivation and controlled agricultural environments. NDIR CO2 sensors can be integrated into monitoring equipment used to measure and manage carbon dioxide levels in greenhouse facilities, plant growth chambers and agricultural research equipment.
High-concentration CO2 measurement is required in selected industrial processes, gas storage systems, fermentation equipment and carbon dioxide monitoring instruments. The MNS-QT221 offers high-concentration measurement range options up to 100% VOL, subject to the selected configuration.
Methane sensors are used in natural gas monitoring equipment, combustible gas detectors, industrial gas leakage monitoring systems and gas safety instruments. NDIR methane detection provides an optical measurement method for monitoring CH4 concentration.
The MNS-QT331 is designed for methane monitoring and offers different LEL and VOL measurement configurations for integration into gas detection equipment.
Industrial safety equipment manufacturers can integrate NDIR methane sensors into selected combustible gas monitoring systems for applications involving natural gas, gas storage and industrial gas handling. The complete instrument must be designed and validated according to the applicable safety and hazardous-area requirements.
NDIR and electrochemical gas sensors use different detection principles. Selecting the correct technology depends primarily on the target gas, measurement range, operating environment and instrument design.
Comparison | NDIR Gas Sensor | Electrochemical Gas Sensor |
|---|---|---|
Detection Principle | Infrared light absorption | Electrochemical reaction |
Typical Target Gases | CO2, CH4 and other suitable infrared-absorbing gases | CO, H2S, NO2, SO2, NH3, Cl2 and other gases, depending on sensor chemistry |
Sensing Mechanism | Optical measurement | Electrical current generated by a chemical reaction |
Main Components | Infrared source, gas chamber and optical detector | Working electrode, counter electrode, reference electrode and electrolyte |
Common Applications | CO2 monitoring, methane detection and gas concentration measurement | Toxic gas monitoring and industrial safety instruments |
Maintenance Considerations | Optical condition, calibration and environmental stability | Electrode condition, electrolyte characteristics and calibration |
For CO2 and methane detection, NDIR technology is an appropriate choice when the sensor model and optical configuration match the target gas and required measurement range. For toxic gases such as CO, H2S, NO2, SO2 and NH3, electrochemical sensing is commonly used.
MANORSHI also supplies electrochemical gas sensors for different industrial monitoring applications. Customers can explore the separate product range according to their target gas requirements.
Explore Electrochemical Gas Sensors >
Selecting an NDIR gas sensor requires evaluating the target gas, measuring range, output interface, power requirements and operating environment. OEM engineers should confirm these parameters before integrating a sensor into a gas detection instrument.
Identify whether the application requires carbon dioxide or methane measurement. The MNS-QT221 is designed for CO2, while the MNS-QT331 is designed for CH4. A sensor calibrated for one gas should not be assumed to measure another gas accurately.
The measurement range should cover the expected gas concentration during normal operation and the maximum concentration that the instrument needs to measure.
For CO2 monitoring, low-concentration applications may require ppm-level ranges, while industrial processes may require percentage-by-volume measurement. For methane detection, determine whether the instrument requires %LEL or %VOL output.
Accuracy indicates how closely the measured concentration corresponds to the reference value. Response time indicates how quickly the sensor responds to a change in gas concentration.
Both MANORSHI NDIR models specify an accuracy of ±5% FS and a response time of T90 less than 30 seconds in the published product range. Always confirm the applicable test conditions and selected configuration in the datasheet.
The output interface must be compatible with the host controller. The MNS-QT221 supports UART and 0.4–2V analog output, while the MNS-QT331 product listing specifies UART communication.
Engineers should also confirm the UART communication protocol, signal level, data format, pin assignment and sampling requirements before circuit development.
Both listed models operate from a 3.3–5V DC power supply and have an average current consumption below 85mA. The power supply and PCB design should accommodate the sensor's startup and normal operating requirements.
Temperature and humidity can affect the performance of optical gas sensing systems. Confirm the sensor's operating temperature, humidity limits and environmental protection requirements against the product datasheet before selecting a model for indoor, outdoor or industrial equipment.
The listed dimensions of both MANORSHI models are 14 × 16mm. Engineers should confirm the exact mechanical drawing, pin layout, mounting clearance and gas inlet arrangement before finalizing the PCB and enclosure design.
MANORSHI supplies NDIR infrared gas sensing components for gas detector manufacturers, HVAC equipment manufacturers, environmental monitoring companies and industrial electronic equipment developers.
For OEM projects, customers should evaluate the sensor together with the complete gas sampling path, electronic interface, power supply, calibration procedure and control software.
Important information for project evaluation includes:
Target gas: CO2 or CH4.
Required measurement range and concentration units.
Required accuracy and response time.
UART or analog output requirements.
Operating voltage and power consumption limits.
PCB dimensions and mechanical installation requirements.
Operating temperature, humidity and environmental conditions.
Sample quantity and estimated annual purchasing volume.
Customers can request product datasheets and available samples for prototype development. Sample availability, minimum order quantity, production lead time and bulk purchasing arrangements should be confirmed according to the selected model and order requirements.
For gas safety applications, the NDIR sensor is a component rather than a complete certified gas detector. The final instrument must undergo appropriate system-level calibration, performance verification and safety compliance assessment for its intended application and destination market.
An NDIR gas sensor is a gas detection device that uses non-dispersive infrared absorption technology. It measures the concentration of a target gas by detecting the absorption of infrared radiation at specific wavelengths. It is commonly used for CO2, methane and other suitable infrared-absorbing gases.
NDIR sensors measure gas concentration through infrared light absorption, while electrochemical sensors generate an electrical signal through a chemical reaction at the electrodes. NDIR technology is commonly used for CO2 and methane measurement, while electrochemical sensors are widely used for toxic gases such as CO, H2S, NO2 and SO2.
MANORSHI currently offers the MNS-QT221 for carbon dioxide (CO2) detection and the MNS-QT331 for methane (CH4) detection. Each model is designed and calibrated for its specified target gas.
The MNS-QT221 supports multiple CO2 measurement ranges, including 0–2000 ppm, 0–5000 ppm, 0–1% VOL, 0–2% VOL, 0–5% VOL and 0–100% VOL. The required range should be specified when ordering and confirmed against the corresponding product configuration.
The MNS-QT331 product range includes 0–100% LEL, 0–5% VOL and 0–100% VOL configurations. Customers should specify their required measurement range and calibration gas when requesting a quotation.
The MNS-QT221 supports UART digital communication and 0.4–2V analog voltage output. The MNS-QT331 product listing specifies UART communication. Confirm the interface level, communication protocol and pin assignment before system integration.
Both the MNS-QT221 and MNS-QT331 are listed with an operating voltage of 3.3–5V DC. The power supply should be designed according to the electrical requirements and startup characteristics specified in the product datasheet.
Both listed models specify a response time of T90 less than 30 seconds. Actual system response can also depend on gas flow, sampling chamber design, installation conditions and signal processing.
NDIR sensors detect target gases through infrared absorption rather than an oxygen-dependent electrochemical reaction. However, pressure, temperature, humidity, gas composition and optical conditions can still influence measurement performance. The applicable sensor datasheet should be reviewed for the intended operating environment.
%LEL expresses gas concentration as a percentage of the lower explosive limit, while %VOL expresses the gas volume as a percentage of the total gas mixture. These are different measurement units. The correct range and calibration settings must be selected according to the target gas and the instrument's intended application.
Yes. NDIR gas sensors can be integrated into portable gas detection equipment when their dimensions, power requirements, output interface and measurement range match the instrument design. The completed detector requires appropriate calibration, performance verification and safety validation.
Sample availability depends on the selected model and current supply conditions. Customers can contact MANORSHI with the required gas type, measurement range and sample quantity to confirm availability, pricing and delivery arrangements.
OEM requirements can be evaluated according to the selected model and project conditions. Customers should provide their measurement range, electrical interface, installation dimensions, operating environment and expected quantity so the technical team can assess suitability and available options.
Looking for an NDIR infrared gas sensor manufacturer for your CO2 or methane detection project? MANORSHI offers compact NDIR sensing components for industrial gas monitoring, HVAC equipment, environmental instruments and OEM gas detectors.
Our product range includes the MNS-QT221 NDIR CO2 sensor and MNS-QT331 NDIR methane sensor, with different measurement ranges and electronic output configurations.
Send us your target gas, required measurement range, output interface, technical requirements and estimated purchasing quantity. Our team can help you review suitable models and provide product information for your project.