| Image | Product Name | Model | Dimension | Rated Voltage | Frequency | SPL | Current | Operating Voltage | Details |
|---|---|---|---|---|---|---|---|---|---|
![]() | MNS-4CO-1000 Electrochemical Carbon Monoxide CO Gas Sensor 0-1000 ppm | MNS-4CO-1000 | 14*16mm | <1.0A | View detail » | ||||
![]() | MNS-4NO-250 Electrochemical Nitric Oxide NO Gas Sensor | MNS-4NO-250 | 20*16mm | <1.0A | View detail » | ||||
![]() | MNS-4O3-10 Electrochemical Ozone O3 Gas Sensor 0-10 ppm | MNS-4O3-10 | 14*16mm | <1.0A | View detail » | ||||
![]() | MNS-4CL2-10 Electrochemical Chlorine Cl2 Gas Sensor 0-10 ppm | MNS-4CL2-10 | 14*16mm | <1.0A | View detail » | ||||
![]() | MNS-4NO2-20 Electrochemical Nitrogen Dioxide NO2 Gas Sensor | MNS-4NO2-20 | 20*16mm | <1.0A | View detail » | ||||
![]() | MNS-4H2S-100 Electrochemical H2S Gas Sensor 0-100 ppm | MNS-4H2S-100 | 14*16mm | <1.0A | View detail » | ||||
![]() | MNS-4SO2-20 Electrochemical Sulfur Dioxide SO2 Gas Sensor | MNS-4SO2-20 | 20*16mm | <1.0A | View detail » | ||||
![]() | MNS-4NH3-100 Electrochemical Ammonia NH3 Gas Sensor | MNS-4NH3-100 | 20*16mm | <1.0A | View detail » |
MANORSHI is an electrochemical gas sensor manufacturer and supplier offering gas sensing components for industrial safety equipment, portable gas detectors, fixed gas monitoring systems and environmental monitoring instruments. Our product range covers carbon monoxide (CO), hydrogen sulfide (H2S), nitrogen dioxide (NO2), nitric oxide (NO), sulfur dioxide (SO2), ammonia (NH3), chlorine (Cl2) and ozone (O3) detection.
Electrochemical gas sensors detect specific target gases through chemical reactions at the sensor electrodes. The resulting electrical current changes in proportion to the gas concentration, allowing electronic instruments to measure and monitor gas levels.
MANORSHI electrochemical gas sensors are available with different measuring ranges, sensitivities, resolutions and response times. They are suitable for integration into portable gas detectors, industrial monitoring equipment, gas leakage alarms and OEM gas detection products.
Whether you are a gas detector manufacturer, industrial safety equipment supplier, environmental monitoring company or gas sensor distributor, MANORSHI provides different sensing solutions to support your product development and purchasing requirements.
Request a QuoteRequest Samples
An electrochemical gas sensor detects a target gas through an electrochemical reaction inside a sensing cell. When gas molecules enter the sensor through a gas-permeable membrane, they interact with the working electrode and participate in oxidation or reduction reactions.
These reactions generate an electrical current that is related to the concentration of the target gas. An external electronic circuit measures and processes this current to calculate the gas concentration, usually expressed in parts per million (ppm).
A typical three-electrode electrochemical sensor includes the following components:
Working Electrode: The primary sensing electrode where the target gas undergoes an electrochemical reaction.
Counter Electrode: Completes the electrochemical reaction and electrical circuit.
Reference Electrode: Helps maintain a stable electrode potential for accurate measurement.
Electrolyte: Provides the ionic conduction path required for the electrochemical reaction.
Gas Diffusion Membrane: Controls the entry of target gas into the sensing cell.
Depending on the sensor model, the cell may operate with zero external bias voltage or require a specified applied bias voltage. The external circuit must be designed according to the individual sensor datasheet.
Because electrochemical sensors can provide a current signal proportional to gas concentration, they are commonly used in compact gas detection instruments where low-concentration toxic gas monitoring is required.
MANORSHI offers electrochemical gas sensors for eight target gases. Each model is designed for a specific gas and measurement range, allowing equipment manufacturers to select a suitable sensing component according to their application requirements.
Product Model | Target Gas | Measurement Range | Sensitivity | Resolution | Response Time |
|---|---|---|---|---|---|
Carbon Monoxide (CO) | 0–1000 ppm | 700 ± 20 nA/ppm | 1 ppm | <30 s | |
Hydrogen Sulfide (H2S) | 0–100 ppm | 0.7 ± 0.25 μA/ppm | 1 ppm | <30 s | |
Chlorine (Cl2) | 0–10 ppm | 600 ± 200 nA/ppm | 0.1 ppm | <60 s | |
Ozone (O3) | 0–10 ppm | 0.85 ± 0.25 μA/ppm | 0.05 ppm | <45 s | |
Nitrogen Dioxide (NO2) | 0–20 ppm | 0.60 ± 0.15 μA/ppm | 0.1 ppm | ≤30 s | |
Nitric Oxide (NO) | 0–250 ppm | 0.4 ± 0.1 μA/ppm | 0.5 ppm | ≤30 s | |
Sulfur Dioxide (SO2) | 0–20 ppm | 0.5 ± 0.1 μA/ppm | 0.1 ppm | ≤30 s | |
Ammonia (NH3) | 0–100 ppm | 100 ± 30 nA/ppm | 1 ppm | ≤60 s |
The specifications above are model-specific reference values. Actual sensor performance depends on test conditions, environmental conditions and the external measurement circuit. Please consult the corresponding product datasheet before finalizing your design.
Electrochemical gas sensors are widely used in portable and fixed gas detection equipment, industrial safety instruments and environmental monitoring systems. The appropriate model depends on the target gas, required measuring range and operating conditions.
Carbon monoxide is a colorless and odorless gas that can be produced by incomplete combustion. Electrochemical CO sensors are used in portable carbon monoxide detectors, industrial safety equipment, boiler monitoring systems, parking garage ventilation controls and indoor air monitoring instruments.
The MANORSHI MNS-4CO-1000 provides a measurement range of 0–1000 ppm and is designed for integration into carbon monoxide detection equipment.
Hydrogen sulfide monitoring is important in wastewater treatment plants, oil and gas facilities, sewage systems, biogas equipment and industrial processing environments. H2S gas detectors use electrochemical sensors to monitor hydrogen sulfide concentrations and provide signals to the instrument's alarm and control system.
The MANORSHI MNS-4H2S-100 offers a 0–100 ppm measurement range, 1 ppm resolution and a response time of less than 30 seconds.
Chlorine gas monitoring is required in water treatment facilities, disinfection systems, chemical processing plants and industrial gas leakage detection equipment. Electrochemical chlorine sensors are suitable for monitoring low concentrations of Cl2 in gas detection systems.
The MANORSHI MNS-4CL2-10 has a 0–10 ppm measurement range and 0.1 ppm resolution, making it suitable for integration into chlorine monitoring equipment.
Ozone is used in water treatment, air purification, disinfection and industrial oxidation processes. Ozone monitoring equipment uses electrochemical O3 sensors to measure ozone concentrations in the surrounding environment or process area.
The MANORSHI MNS-4O3-10 provides a 0–10 ppm measuring range, 0.05 ppm resolution and a response time of less than 45 seconds.
Nitrogen dioxide monitoring is relevant to industrial emission monitoring, combustion equipment, vehicle exhaust analysis and environmental air quality instruments. Electrochemical NO2 sensors can be integrated into portable and fixed gas detection systems.
The MANORSHI MNS-4NO2-20 has a 0–20 ppm measurement range, 0.1 ppm resolution and a response time of 30 seconds or less.
Nitric oxide monitoring is used in selected industrial process monitoring, environmental measurement, petrochemical equipment and pharmaceutical production applications. NO sensors are different from NO2 sensors and should be selected according to the target gas and required measurement range.
The MANORSHI MNS-4NO-250 provides a 0–250 ppm measurement range and uses a potentiostatic electrochemical sensing principle with a specified bias voltage of +300 mV.
Sulfur dioxide sensors are used in industrial emission monitoring, combustion-related equipment, environmental protection instruments and industrial gas detection systems. SO2 monitoring can help equipment manufacturers develop gas monitoring solutions for industrial and environmental applications.
The MANORSHI MNS-4SO2-20 offers a 0–20 ppm measurement range, 0.1 ppm resolution and a response time of 30 seconds or less.
Ammonia gas monitoring is relevant to industrial refrigeration, chemical processing, fertilizer production, agricultural facilities and ammonia leakage detection systems. Electrochemical ammonia sensors are used in gas detectors and monitoring instruments designed for NH3 measurement.
The MANORSHI MNS-4NH3-100 provides a 0–100 ppm measurement range, 1 ppm resolution and a response time of 60 seconds or less.
Choosing an electrochemical gas sensor requires evaluating the target gas, measurement range, sensitivity, response time and electrical characteristics. A suitable sensor must match both the gas detection requirements and the design of the complete electronic instrument.
First, identify the gas that needs to be detected. CO, H2S, Cl2, O3, NO2, NO, SO2 and NH3 require different sensing characteristics. Sensors designed for one gas should not be assumed to provide accurate measurements of another gas.
The measuring range should cover the expected gas concentration in the application. For example, the MNS-4CO-1000 measures CO from 0 to 1000 ppm, while the MNS-4CL2-10 is designed for chlorine measurement from 0 to 10 ppm.
The maximum overload specification is different from the normal measurement range. Prolonged exposure above the specified limits may affect sensor performance and service life.
Sensitivity describes the change in sensor output per unit change in gas concentration. It is commonly expressed in nA/ppm or μA/ppm for electrochemical sensors.
Resolution indicates the smallest concentration increment specified for measurement. Both parameters should be considered when selecting a sensor for low-concentration gas monitoring.
Response time indicates how quickly the sensor responds to a change in gas concentration under specified test conditions. A shorter response time may be important for applications requiring rapid gas monitoring and alarm response.
Electrochemical gas sensors can have different bias voltage requirements. Many MANORSHI models specify 0 mV bias voltage, while the MNS-4NO-250 specifies +300 mV. Engineers should follow the individual product datasheet when designing the sensor interface circuit.
The sensor output current generally requires an appropriate signal-conditioning circuit, such as a transimpedance amplifier, to convert the current signal into a measurable voltage for the instrument's processing system.
Cross-sensitivity occurs when gases other than the target gas produce a response in the sensor. The level of interference depends on the sensor chemistry and the interfering gas concentration.
For applications involving multiple gases, review the cross-interference data for each sensor model. This is particularly important when designing multi-gas detectors for industrial environments.
Temperature, humidity, pressure, storage conditions and exposure to high gas concentrations can affect sensor performance. Confirm that the selected model is suitable for the actual operating environment.
Electrochemical sensor service life varies by model and operating conditions. Follow the manufacturer's storage, calibration and replacement recommendations.
MANORSHI electrochemical gas sensors are designed for integration into gas detection instruments and monitoring equipment. OEM manufacturers can select models according to their target gas, detection range, electrical requirements and mechanical installation conditions.
Typical OEM integration considerations include:
Target gas and required measuring range.
Sensor dimensions and PCB installation requirements.
Sensitivity, resolution and response time.
Bias voltage and signal-conditioning circuit design.
Cross-sensitivity and calibration requirements.
Operating temperature, humidity and pressure.
Expected annual demand and production requirements.
For prototype development, customers can request available samples to evaluate sensor performance in their own electronic instruments. Before mass production, the complete gas detection system should undergo appropriate calibration, validation and compliance testing according to its intended application and destination market.
Please provide your technical requirements, reference model, expected order quantity and application information so our team can help identify suitable electrochemical gas sensor models.
An electrochemical gas sensor is a gas detection component that uses chemical reactions at electrodes to generate an electrical signal. The signal changes according to the concentration of the target gas. These sensors are commonly used in portable gas detectors, industrial safety instruments and environmental monitoring equipment.
Electrochemical gas sensors are available for various toxic and reactive gases, including carbon monoxide (CO), hydrogen sulfide (H2S), chlorine (Cl2), ozone (O3), nitrogen dioxide (NO2), nitric oxide (NO), sulfur dioxide (SO2) and ammonia (NH3). The correct model depends on the target gas and required measurement range.
Gas molecules enter the sensor through a diffusion membrane and react at the working electrode. This reaction generates an electrical current that is related to the gas concentration. An external signal-conditioning circuit measures the current and converts it into a concentration reading, usually expressed in ppm.
Electrochemical sensors use chemical reactions to detect specific gases and are commonly used for toxic gas monitoring, including CO, H2S, NO2 and Cl2. NDIR sensors use infrared absorption to measure gases such as CO2 and methane. The two technologies have different operating principles and are selected according to the target gas and application requirements.
Sensitivity indicates how much the sensor output changes for a given change in gas concentration. Electrochemical sensor sensitivity is commonly expressed in nA/ppm or μA/ppm. It is an important parameter when designing the signal-conditioning circuit and evaluating low-concentration measurement performance.
Response time depends on the target gas, sensor design and model. MANORSHI models have specified response times ranging from less than 30 seconds to 60 seconds or less. Please refer to the individual datasheet for the exact response-time specification and test conditions.
NO is nitric oxide, while NO2 is nitrogen dioxide. They are different chemical gases and require different sensing characteristics. MANORSHI offers the MNS-4NO-250 for nitric oxide detection and the MNS-4NO2-20 for nitrogen dioxide detection. These models should not be treated as interchangeable.
The bias voltage requirement depends on the sensor model. Several MANORSHI models specify 0 mV bias voltage, while the MNS-4NO-250 requires +300 mV. Always follow the corresponding datasheet when designing the electrical interface.
Cross-sensitivity refers to a sensor response caused by gases other than its primary target gas. It can affect measurement accuracy when multiple gases are present in the same environment. Engineers should review the cross-interference data for the selected model before integrating it into a multi-gas detection system.
Service life varies according to sensor model, target gas exposure, storage conditions and operating environment. MANORSHI product specifications list different expected service lives depending on the model. Regular calibration, correct storage and replacement according to the manufacturer's recommendations are important for maintaining measurement performance.
Yes. Electrochemical sensors are commonly integrated into portable gas detectors because of their compact construction and suitability for detecting specific toxic gases. The final instrument requires appropriate signal processing, calibration, power management and safety validation.
Sample availability depends on the selected model and current supply conditions. OEM customers can contact MANORSHI with their required gas type, model, sample quantity and application information to confirm availability and purchasing arrangements.
Looking for an electrochemical gas sensor manufacturer for your portable gas detector, industrial safety instrument or environmental monitoring project?
MANORSHI supplies electrochemical sensors for CO, H2S, Cl2, O3, NO2, NO, SO2 and NH3 detection. Our product range supports different measuring ranges, sensitivities and response-time requirements for OEM equipment manufacturers and distributors.
Send us your target gas, required measurement range, technical specifications and estimated purchase quantity. Our team can help you review available models and arrange further product information.