| Image | Product Name | Model | Accuracy | Frequency Range | Voltage | Current | Measure Range |
|---|---|---|---|---|---|---|---|
![]() | MNSLL-H101 80GHz Silo Radar Level Sensor 4-20mA | MNSLL-H101 | ±1mm | 76GHz~81GHz | 12-24V | 4-20mA | 0-120m |
![]() | MNSLL-H108 80GHz Radar Liquid Level Sensor 4-20mA | MNSLL-H108 | ±1mm | 76GHz~81GHz | 12-24V | 4-20mA | 0-120m |
![]() | MNSLL-H106 Radar Level Sensor 4-20mA for Liquid and Solid Level Measurement | MNSLL-H106 | ±1mm | 76GHz~81GHz | 12-24V | 4-20mA | 0-120m |
![]() | MNSLL-H105 Cement Silo Radar Level Sensor 4-20mA | MNSLL-H105 | ±1mm | 76GHz~81GHz | 12-24V | 4-20mA | 0-120m |
![]() | MNSLL-H103 80GHz Radar Liquid Level Sensor for Corrosive Liquids | MNSLL-H103 | ±1mm | 76GHz~81GHz | 12-24V | 4-20mA | 0-120m |
![]() | MNSLL-H102 High Temperature Radar Liquid Level Sensor 4-20mA | MNSLL-H102 | ±1mm | 76GHz~81GHz | 12-24V | 4-20mA | 0-120m |
MANORSHI is a radar level sensor manufacturer and supplier specializing in 80GHz-class non-contact radar measurement instruments for industrial liquid tanks, chemical storage vessels, cement silos and bulk material storage systems. Our product range includes six radar level sensor models designed for different industrial measurement applications.
MANORSHI radar level sensors operate in the 76–81GHz frequency band according to the current product specifications. Selected product configurations are listed with measurement accuracy of ±1mm, measuring ranges up to 120 meters, 12–24V power supply and 4–20mA analog output.
Our radar level measurement range includes general-purpose liquid level sensors, solid material level sensors, cement silo radar sensors, corrosive liquid radar sensors and high-temperature radar level sensors. These products provide non-contact measurement for industrial tanks, storage vessels and process equipment.
The MANORSHI MNSLL series includes MNSLL-H101, MNSLL-H102, MNSLL-H103, MNSLL-H105, MNSLL-H106 and MNSLL-H108. Each model is designed for a specific measurement application, helping engineers select suitable equipment according to the measured medium and operating environment.
MANORSHI supplies radar level measurement products for industrial automation companies, tank manufacturers, chemical processing equipment suppliers, cement plant equipment manufacturers, water treatment companies and instrumentation distributors. Product datasheets, mechanical drawings and samples can be requested for engineering evaluation and OEM projects.
Request a Radar Level Sensor QuoteRequest Technical Datasheets
MANORSHI offers six radar level sensor models for different industrial applications. The series covers liquid measurement, solid material measurement, cement silo monitoring, corrosive liquid storage and high-temperature liquid measurement.
Model | Product Type | Frequency Range | Accuracy | Measuring Range | Output |
|---|---|---|---|---|---|
Silo Radar Level Sensor | 76–81GHz | ±1mm listed | 0–120m listed | 4–20mA | |
Liquid Radar Level Sensor | 76–81GHz | ±1mm listed | 0–120m listed | 4–20mA | |
Liquid and Solid Level Sensor | 76–81GHz | ±1mm listed | 0–120m listed | 4–20mA | |
Cement Silo Radar Sensor | 76–81GHz | ±1mm listed | 0–120m listed | 4–20mA | |
Corrosive Liquid Radar Sensor | 76–81GHz | ±1mm listed | 0–120m listed | 4–20mA | |
High-Temperature Radar Sensor | 76–81GHz | ±1mm listed | 0–120m listed | 4–20mA |
The current MANORSHI product category lists a 76–81GHz frequency range, ±1mm accuracy, 0–120m measuring range, 12–24V power supply and 4–20mA output for the six models. These are published category specifications. The actual minimum measuring distance, process conditions and available configurations must be confirmed in the individual model datasheet.
The 4–20mA value represents the analog signal output, not the sensor's power consumption. Please check the electrical wiring diagram for the exact power supply arrangement and output configuration.
The MNSLL-H101 is designed for non-contact level monitoring in silos and bulk material storage vessels. It can be evaluated for cement powder, grains, granules and other industrial solid materials according to the material properties and silo geometry.
View MNSLL-H101 Product Details >
The MNSLL-H108 is a radar level sensor for industrial liquid storage and process vessel monitoring. It provides a non-contact measurement option for applications requiring continuous liquid level information.
View MNSLL-H108 Product Details >
The MNSLL-H106 is designed for level measurement of liquids and solid materials. It can be considered for storage tanks, process vessels and bulk material applications where non-contact measurement is required.
View MNSLL-H106 Product Details >
The MNSLL-H105 is intended for cement silo and bulk material level monitoring. Its application should be evaluated according to silo height, dust conditions, material surface characteristics and installation position.
View MNSLL-H105 Product Details >
The MNSLL-H103 is listed for corrosive liquid level measurement. It can be evaluated for chemical storage tanks and industrial process vessels where non-contact level measurement is required.
Before selecting this model, confirm the compatibility of the antenna, housing, sealing components and process connection materials with the chemical composition, concentration and operating temperature of the measured liquid.
View MNSLL-H103 Product Details >
The MNSLL-H102 is designed for high-temperature liquid level measurement applications. It can be evaluated for industrial process vessels and storage tanks operating under elevated temperature conditions.
The maximum process temperature must be confirmed according to the selected sensor configuration. Engineers should also check the antenna material, mounting connection and any temperature isolation requirements before installation.
View MNSLL-H102 Product Details >
Compare Radar Level Sensor Models
A radar level sensor is a non-contact industrial measurement instrument that uses microwave electromagnetic signals to measure the distance between the sensor and the surface of a liquid or solid material. The instrument calculates the material level based on the reflected radar signal and a configured tank or silo reference height.
Unlike contact-based level measurement instruments, a radar level sensor does not require a probe or sensing element to be immersed in the measured medium. This makes it suitable for selected applications involving corrosive liquids, bulk solids and industrial process vessels.
Radar level sensors are widely used in chemical processing, water treatment, oil and gas, cement production, food processing, pharmaceutical manufacturing and industrial material storage.
Non-contact measurement without direct immersion in the measured medium.
Continuous level monitoring for tanks, vessels and silos.
Suitable configurations for liquid and solid material measurement.
Reduced mechanical wear compared with contact-based sensing elements.
Suitable for selected corrosive and difficult-to-measure media.
4–20mA output for integration with industrial control systems.
Available measuring configurations for different tank and silo heights.
No moving mechanical sensing parts in the measurement path.
An 80GHz radar level sensor transmits microwave signals toward the surface of a liquid or solid material. The reflected signal returns to the antenna and is processed by the electronic measurement system to determine the distance between the sensor and the material surface.
The measured distance is then converted into a level value using the configured reference height of the tank or silo. Depending on the radar architecture, distance calculation may use the signal travel time or the frequency difference between transmitted and received signals.
The radar antenna transmits high-frequency microwave signals toward the material surface. The antenna design determines the signal radiation pattern and influences the measurement coverage inside the vessel.
When the microwave signal reaches the liquid or solid material surface, part of the energy is reflected toward the radar antenna. The reflected signal depends on the material's dielectric properties, surface condition, geometry and installation environment.
The electronic processing unit analyzes the reflected radar signal and calculates the distance from the antenna reference point to the material surface. The signal processing method depends on the sensor's radar architecture.
The instrument uses the configured reference height and measured distance to calculate the material level. For a tank with a known reference height, the liquid level can be calculated by subtracting the measured distance from the configured tank height.
The radar instrument converts the calculated level value into an electrical output signal. MANORSHI radar level sensor models are listed with 4–20mA output for integration with compatible PLCs, industrial controllers and monitoring systems.
Radar liquid level sensors provide continuous non-contact measurement of liquids in storage tanks, process vessels and industrial containers. The radar antenna is installed above the liquid surface and measures the reflected microwave signal without direct immersion in the liquid.
This measurement method can be considered for water, industrial liquids, chemical storage and selected process applications. The appropriate sensor configuration depends on liquid dielectric properties, tank geometry, temperature, pressure and installation conditions.
Industrial storage tanks use radar level sensors to monitor liquid inventory and support process control. Continuous level information can be transmitted to a PLC or monitoring system through a compatible 4–20mA interface.
Chemical storage tanks may contain liquids that are corrosive or difficult to measure using contact-based instruments. A non-contact radar sensor can reduce direct exposure of the measuring instrument to the liquid, although the antenna, seals and process connection still require chemical compatibility verification.
Water storage and wastewater treatment systems require continuous level monitoring for storage management and process control. Radar level measurement can be evaluated for open or enclosed water tanks according to the installation environment and required measurement range.
High-temperature industrial vessels require radar level sensors with suitable process temperature ratings and compatible antenna structures. The MNSLL-H102 is listed as a high-temperature radar liquid level sensor. Confirm the maximum process temperature and installation requirements in its approved datasheet.
Radar solid level sensors are used to measure the height of bulk materials stored in silos, hoppers and industrial storage vessels. Typical materials include cement powder, mineral powders, grains, granules and other bulk solids.
Non-contact radar measurement can provide continuous level information without requiring a mechanical probe to enter the stored material. This can reduce mechanical wear and simplify selected silo monitoring installations.
Cement silos require level monitoring for material inventory management and production planning. Radar sensors can measure the distance to the cement powder surface without direct contact with the stored material.
The MNSLL-H101 and MNSLL-H105 are listed for silo and cement silo level measurement applications. The final model should be selected according to silo height, dust conditions, filling position and material characteristics.
Powder and granular material storage systems can use radar level sensors for continuous inventory monitoring. Engineers should evaluate material dielectric properties, surface angle, dust concentration and the position of filling and discharge equipment.
Industrial hoppers and storage vessels often contain uneven material surfaces during filling and discharge. The antenna position and radar beam characteristics should be considered to reduce interference from vessel walls and internal structures.
Radar level sensors can be considered for corrosive liquid measurement because the microwave signal measures the liquid surface without requiring a sensing probe to be immersed in the medium. This can reduce direct contact between the measurement system and the stored chemical.
The MANORSHI MNSLL-H103 is listed for corrosive liquid radar level measurement. It is intended for evaluation in chemical storage tanks and industrial process vessels where non-contact measurement is required.
Although radar measurement does not require direct immersion of a sensing probe, the antenna and process connection may still be exposed to chemical vapors, splashes or condensation. Their materials must be compatible with the chemical composition and concentration.
Before selecting a radar level sensor for aggressive liquids, provide the manufacturer with the chemical name, concentration, process temperature and operating pressure. Confirm antenna, seal and housing compatibility using the approved material specifications.
Non-contact radar measurement can support continuous chemical tank level monitoring and reduce the need for mechanical components inside the liquid. The installation must still account for tank geometry, vapors, condensation, nozzle structure and the dielectric properties of the measured medium.
View MNSLL-H103 Corrosive Liquid Radar Level Sensor >
High-temperature radar level sensors are designed for industrial applications where the measured medium or process vessel operates at elevated temperatures. The sensor must have a suitable process temperature rating and an antenna structure compatible with the installation environment.
The MANORSHI MNSLL-H102 is listed as a high-temperature radar liquid level sensor for industrial process measurement. Its selection should be based on the actual process temperature, pressure, installation height and required measuring range.
Process temperature refers to the temperature of the measured medium, while ambient temperature refers to the temperature surrounding the sensor housing. These values may have different permitted limits.
Engineers should confirm the maximum process temperature, pressure, antenna material and installation arrangement before selecting a high-temperature radar sensor. Additional thermal isolation or an extended process connection may be required depending on the equipment design.
View MNSLL-H102 High-Temperature Radar Level Sensor >
Radar level sensor specifications determine whether an instrument is suitable for the intended tank, silo or industrial process. Engineers and purchasing teams should evaluate the following technical parameters before selecting a model.
Operating frequency indicates the microwave frequency range used by the radar level sensor. MANORSHI's current product category lists a frequency range of 76–81GHz, commonly described as the 80GHz radar band.
The shorter wavelength of high-frequency radar can support compact antenna structures and focused beam designs. Actual beam angle and measurement performance depend on the antenna configuration.
Measuring range indicates the distance over which the sensor can measure the material surface under specified conditions. The current MANORSHI category lists a range of 0–120 meters for its six models.
The actual usable range depends on the selected model, measured medium, dielectric properties, antenna configuration and installation environment. The minimum measuring distance and blind zone should be confirmed in the product datasheet.
Measurement accuracy describes the difference between the indicated measurement and the actual material level under specified conditions. MANORSHI's current product category lists ±1mm accuracy for the six radar level sensor models.
The final accuracy in an industrial installation can be influenced by measurement range, surface characteristics, installation geometry and process conditions. Request the model-specific accuracy specification and test conditions for engineering approval.
The blind zone is the area close to the radar antenna where reliable level measurement may not be available. It is also related to the minimum measuring distance specified by the manufacturer.
The blind zone is important when selecting a radar sensor for short tanks, small vessels and installations where the liquid surface can approach the antenna. Confirm the minimum measuring distance before equipment installation.
Beam angle describes the angular width of the transmitted radar signal. A narrower beam can help reduce reflections from tank walls, internal pipes and other obstructions when the sensor is correctly positioned.
The antenna diameter, shape and mounting position influence the beam characteristics. Customers should request the actual beam angle and antenna drawing for the selected MANORSHI model.
The 4–20mA analog output is widely used in industrial process control. It allows the radar level measurement value to be transmitted to compatible PLCs, industrial controllers, indicators and monitoring systems.
The current MANORSHI category lists 4–20mA output. Customers requiring HART, RS485 or Modbus communication should confirm the actual availability of these interfaces for the selected model before ordering.
The current MANORSHI product category lists a 12–24V power supply range. The exact supply type, wiring arrangement, polarity and power consumption should be confirmed in the model-specific electrical datasheet.
Antenna and housing materials influence chemical compatibility, environmental resistance and mechanical installation. Common materials used in industrial radar level instruments include stainless steel, PTFE, PVDF, PP and engineering plastics.
The actual MANORSHI antenna and sealing materials should be confirmed for each model. For corrosive liquid applications, obtain the material compatibility information before finalizing the purchase specification.
Process connections determine how the radar sensor is installed on the tank or vessel. Common industrial options include threaded connections and flanges in different sizes and standards.
Before ordering, confirm the thread standard, flange dimensions, pressure rating, nozzle height and available installation space.
Process temperature and pressure define the operating conditions of the measured medium. These limits must be compatible with the sensor antenna, housing, seals and process connection.
For high-temperature and pressurized applications, request the maximum process temperature and pressure ratings for the selected model rather than relying only on the general product category description.
Radar and ultrasonic level sensors both provide non-contact level measurement, but they use different physical principles. Radar sensors use microwave electromagnetic signals, while ultrasonic sensors use acoustic sound waves transmitted through air.
Comparison | Radar Level Sensor | Ultrasonic Level Sensor |
|---|---|---|
Measurement Principle | Microwave electromagnetic signals | Ultrasonic acoustic waves |
Signal Propagation | Electromagnetic wave propagation | Sound propagation through air |
Air Temperature Influence | Generally less affected by air temperature changes | Sound velocity changes with air temperature |
Vapor and Gas Conditions | Suitable for selected vapor and industrial process conditions | Vapor and gas composition can affect acoustic propagation |
Typical Applications | Chemical tanks, process vessels and silos | Water tanks and general liquid measurement |
Selection Factors | Frequency, antenna, dielectric properties and installation | Temperature, sound propagation and target surface |
Radar level measurement is often preferred for industrial applications involving changing air temperatures, vapor or challenging installation conditions. Ultrasonic measurement can be suitable for general water and liquid applications where acoustic propagation conditions are stable.
Neither technology is suitable for every application. The measured medium, dielectric properties, tank geometry, surface conditions and installation environment should be evaluated before selecting the sensor.
Selecting a suitable radar level sensor requires matching the measuring range, accuracy, medium, operating frequency, output signal and installation conditions to the actual industrial application.
Determine whether the sensor will measure water, chemicals, oil, cement powder, grains, granules or other bulk materials. Liquid and solid applications may require different antenna configurations and signal processing settings.
Measure the height of the tank or silo and calculate the maximum distance between the antenna and the material surface. Include the minimum measuring distance, blind zone and required measurement margin in the equipment selection.
Determine the accuracy required for inventory monitoring or process control. Compare the model-specific accuracy specification and the conditions under which it is measured.
Evaluate the radar frequency, antenna dimensions and beam angle according to the vessel geometry. A suitable antenna configuration helps reduce unwanted reflections from tank walls, internal structures and other obstructions.
Confirm the minimum measuring distance and blind zone of the selected model. This is especially important for short tanks and vessels where the material surface can approach the antenna.
For corrosive liquid applications, identify the chemical composition, concentration and process temperature. Confirm the compatibility of the antenna, housing, sealing components and process connection materials.
Check the maximum and minimum process temperature and pressure. These values must remain within the permitted limits of the selected sensor configuration.
Determine whether the control system requires 4–20mA analog output or another communication interface. Confirm the actual interface supported by the selected model and its compatibility with the receiving PLC or controller.
Consider vessel diameter, nozzle height, internal pipes, agitators, filling points and discharge structures. The radar antenna should have a suitable measurement path toward the target material surface.
Before bulk purchasing, request the product datasheet, mechanical drawing, wiring diagram, antenna material specification and relevant environmental test documentation. Confirm that the selected instrument matches the process and installation requirements.
Correct installation is important for stable radar level measurement. The antenna position, tank geometry, reference height and material surface conditions can influence measurement performance.
Install the radar sensor where the antenna has a suitable measurement path toward the material surface. Avoid positions where tank walls, internal pipes, agitators or other structures may create unwanted reflections within the radar beam.
Check nozzle diameter, nozzle height and internal geometry before selecting the antenna and process connection. The antenna should be installed according to the product mechanical drawing and manufacturer's recommendations.
Configure the tank or silo reference height according to the actual vessel dimensions. Verify the empty distance, maximum material level and minimum measuring distance during commissioning.
Connect the sensor according to the approved wiring diagram. Verify the power supply, 4–20mA signal connection, grounding and cable arrangement before commissioning.
Inspect the antenna surface, housing, seals and mounting connection periodically. Check for material buildup, mechanical damage and signs of moisture ingress according to the process environment and maintenance schedule.
Compare the displayed level with a known reference measurement during commissioning and periodic maintenance. Investigate unexpected fluctuations by checking the installation position, reference settings, process conditions and reflected signal quality.
MANORSHI supplies radar level measurement products for industrial automation companies, tank manufacturers, chemical processing equipment suppliers, cement plant equipment manufacturers, water treatment equipment suppliers and instrumentation distributors.
Our MNSLL radar level sensor series includes different product configurations for liquid measurement, solid material storage, corrosive chemical tanks and high-temperature industrial processes. OEM and ODM project requirements can be evaluated according to the selected model and application conditions.
For radar level sensor project evaluation, customers can provide the following information:
Measured medium: water, chemical liquid, oil, powder or bulk solids.
Tank or silo height and required measuring range.
Required measurement accuracy and minimum measuring distance.
Operating frequency and antenna requirements.
Process temperature and operating pressure.
Chemical composition and material compatibility requirements.
Required 4–20mA output or other communication interfaces.
Power supply voltage and wiring configuration.
Flange, threaded or other process connection requirements.
Housing, antenna and sealing material requirements.
Environmental protection and certification requirements.
Sample quantity and estimated annual purchasing volume.
Customers can request available product datasheets, mechanical drawings, wiring information and samples for engineering evaluation. Custom configurations, packaging, minimum order quantity and production lead time can be discussed according to the selected model and project requirements.
Discuss Your Radar Level Sensor OEM Project
A radar level sensor is a non-contact industrial measurement instrument that uses microwave electromagnetic signals to measure the distance between the sensor and the surface of a liquid or solid material. It calculates the material level using the reflected signal and a configured reference height.
An 80GHz radar level sensor transmits microwave signals toward the material surface and receives the reflected energy. Its electronic processing system calculates the distance to the surface and converts the measurement into a continuous level value.
The current MANORSHI product category lists an operating frequency range of 76–81GHz for the six MNSLL radar level sensor models. This is commonly referred to as the 80GHz radar frequency band.
The current MANORSHI product category lists a measuring range of 0–120 meters for the six models. The actual minimum measuring distance and usable range should be confirmed in the individual model datasheet.
The current product category lists ±1mm accuracy for the six radar level sensor models. Confirm the model-specific test conditions and measurement accuracy before using this value in an industrial equipment specification.
The current MANORSHI product category lists 4–20mA analog output. This signal can be connected to compatible PLCs, industrial controllers and level monitoring systems. Other communication interfaces should be confirmed for the selected model.
The current product category lists a 12–24V power supply range. Check the individual datasheet for the exact supply type, wiring arrangement and electrical requirements.
Yes. Selected radar level sensors are designed for liquid and solid material measurement. Applications include industrial liquid tanks, cement silos, powder storage, grains and other bulk material vessels. The selected antenna and sensor configuration should match the measured medium.
The MNSLL-H101 and MNSLL-H105 are listed for silo and cement silo level measurement applications. The appropriate model should be selected according to silo height, dust conditions, filling position and material characteristics.
The MNSLL-H103 is listed for corrosive liquid level measurement. Before purchasing, confirm the chemical compatibility of the antenna, seals, housing and process connection materials with the actual chemical composition and concentration.
The MNSLL-H102 is listed as a high-temperature radar liquid level sensor. The maximum permissible process temperature and pressure must be confirmed in the model-specific datasheet before selecting it for a high-temperature application.
80GHz and 26GHz radar sensors use different microwave frequency bands. Higher-frequency radar can support smaller antenna structures and narrower beam designs. Actual measurement accuracy and performance depend on antenna design, signal processing and installation conditions rather than frequency alone.
Radar level sensors use microwave electromagnetic signals, while ultrasonic level sensors use sound waves. Radar measurement is generally less affected by air temperature changes and certain vapor conditions. Ultrasonic measurement depends on sound propagation through the air. The correct technology depends on the medium and installation environment.
The blind zone is the area close to the antenna where reliable level measurement may not be available. It is also related to the sensor's minimum measuring distance. Check the blind zone in the individual datasheet, especially for short tanks and small vessels.
Yes. The dielectric properties of the measured liquid influence radar signal reflection. Low-dielectric materials may produce weaker reflected signals, so the sensor's minimum dielectric constant and signal processing capability should be checked before selecting a model.
Radar level sensors can be used in selected dusty silo applications. However, dust concentration, material surface characteristics, antenna design and installation conditions should be evaluated to ensure reliable measurement performance.
Yes. Radar sensors measure the liquid surface using microwave signals without immersing a sensing probe in the chemical. However, the antenna and other exposed components may still contact chemical vapors or splashes. Material compatibility must be verified for the specific chemical and process conditions.
Customers can contact MANORSHI to request available product datasheets, mechanical drawings, wiring information and installation specifications for selected radar level sensor models.
Customers can contact MANORSHI to confirm sample availability for selected radar level sensor models. Providing the measured medium, required range, process conditions and model number helps identify a suitable product for engineering evaluation.
MANORSHI can evaluate OEM and ODM project requirements according to the selected radar level sensor model and technical specifications. Customers can provide tank drawings, process conditions, required measurement range and electrical interface information for assessment.
Looking for a radar level sensor manufacturer for your industrial liquid tank, chemical storage vessel, cement silo or bulk material measurement project?
MANORSHI supplies 80GHz-class radar level sensors with different product configurations for liquid measurement, solid material storage, corrosive chemical applications and high-temperature industrial processes.
Send us your measured medium, tank height, required accuracy, process temperature, pressure, output signal and installation requirements. Our team can help evaluate suitable MNSLL radar level sensor models and provide available technical documentation for your project.
Contact Us
Stay Connected