| Image | Product Name | Model | Dimension | Rated Voltage | Frequency | SPL | Current | Operating Voltage | Details |
|---|---|---|---|---|---|---|---|---|---|
![]() | Small 3V Piezo Alarm Sound Buzzer | MSET09G | 9.6 * 5mm | 3V | 2700±500Hz | ≥85dB@10cm | ≤60mA | 2-4V | View detail » |
![]() | 1.5V Electronic Magnetic Passive Sound Transducers Buzzer | MSET09A | 9 * 4mm | 1.5Vp-p | 2730±500Hz | ≥85dB@10cm | ≤80mA | 1~2Vp-p | View detail » |
![]() | 2700Hz 1.5v Magnetic Buzzer with Remote Control | MSET09B | 9 * 5mm | 3Vp-p | 2730±500Hz | ≥87dB@10cm | ≤70mA | 2~4Vp-p | View detail » |
![]() | 1.5v Side Hole Magnetic Buzzer 3v Electromagnetic Buzzer | MSET09C | 9 * 4mm | 3Vo-p | 2731±500Hz | ≥85dB@10cm | ≤90mA | 2.5~4.2Vp-p | View detail » |
![]() | 1.5V 3V 5V 2371Hz 9650 Lateral Sound Electromagnetic Patch Buzzer | MSET10A | 9.6 *5mm | 5Vo-p | 2731±500Hz | ≥85dB@10cm | ≤80mA | 4~7Vp-p | View detail » |
![]() | 1.5V Small Magnetic Buzzer Electric Bell Warning Transducer | MSET10C | 9.6 *5mm | 1.5Vp-p | 2730±500Hz | ≥86dB@10cm | ≤80mA | 1~2Vp-p | View detail » |
![]() | 1.5V 5V 12V 85dB Split Magnetic Buzzer | MSET12A | 11.8 * 9mm | 5Vp-p | 2000±500Hz | ≥85dB@10cm | ≤50mA | 3~7Vp-p | View detail » |
![]() | 1.5V V 70dB 80dB Low Voltage Split Magnetic Buzzer | MSET12B | 12 * 7.5mm | 1.5Vp-p | 2048±500Hz | ≥70dB@10cm | ≤70mA | 1~2Vp-p | View detail » |
![]() | 1.5V 70dB 75dB Electronic Magnetic Passive Sound Transducers Buzzer | MSET12C | 12 * 5.4mm | 3Vp-p | 2048±500Hz | ≥75dB@10cm | ≤30mA | 1.5~3Vp-p | View detail » |
![]() | 1.5v 85dbpassive Electronic Magnetic Buzzer | MSET12D | 12 * 8.5mm | 1.5Vp-p | 2400±300Hz | ≥85dB@10cm | ≤30mA | 3~5Vp-p | View detail » |
![]() | 1.5V 6V 12V 80dB 85dB Alarm Magnetic Ac Buzzer | MSET16A | 16 * 14mm | 6Vp-p | 2048±500Hz | ≥85dB@10cm | ≤40mA | 4~8Vp-p | View detail » |
MANORSHI is a magnetic transducer manufacturer and supplier specializing in externally driven electromagnetic sound transducers for electronic equipment, alarm systems, doorbells, household appliances and industrial control devices.
Our magnetic transducer range includes compact electromagnetic sound components with different dimensions, rated drive voltages, resonant frequencies, sound pressure levels and current consumption characteristics. These components are designed for electronic products that require external signal control and reliable audible feedback.
Unlike active magnetic buzzers with integrated oscillation circuits, externally driven magnetic transducers require an electrical signal from an external driver or controller. This configuration allows engineers to control the driving frequency and sound activation through the electronic circuit.
MANORSHI supplies magnetic transducers for electronic component distributors, OEM manufacturers, PCB designers, security equipment producers and electronic device developers. Different voltage and acoustic configurations are available for engineering evaluation and bulk purchasing.
Request a Magnetic Transducer QuoteRequest Product Samples
A magnetic transducer is an electromagnetic sound-generating component that converts electrical signals into audible sound through the movement of a vibrating diaphragm. It generally consists of an electromagnetic coil, magnetic circuit, diaphragm, housing and electrical terminals.
When an alternating or periodic electrical signal is applied to the coil, the resulting magnetic force causes the diaphragm to vibrate. This mechanical movement generates sound waves at a frequency determined by the driving signal and the mechanical characteristics of the transducer.
In externally driven magnetic transducers, the oscillation signal is generated by an external electronic circuit rather than an integrated oscillator. This allows the host device to control sound activation, timing and, within the component's operating limits, frequency.
Magnetic transducers are commonly used in electronic alarms, doorbells, control panels, communication devices and other equipment requiring audible notifications.
Electromagnetic Coil: Generates a magnetic field when an electrical current passes through the winding.
Magnetic Circuit: Directs and concentrates the magnetic flux within the sound-generating structure.
Vibrating Diaphragm: Responds to changing magnetic force and generates mechanical vibration.
Housing: Protects the internal components and supports the acoustic structure.
Electrical Terminals: Connect the transducer to the external driving circuit.
Sound Outlet: Allows the generated sound to radiate from the component.
An externally driven magnetic transducer operates through electromagnetic induction and diaphragm vibration. The external controller supplies a periodic electrical signal to the coil, generating a changing magnetic field that drives the diaphragm.
The operating process involves the following stages:
An external controller or signal generator produces an electrical driving waveform.
The electrical signal passes through the electromagnetic coil.
The coil generates a changing magnetic field.
The magnetic force causes the diaphragm to move.
Repeated diaphragm movement produces mechanical vibration and audible sound waves.
The driving frequency determines the main electrical excitation frequency. The resulting acoustic response also depends on the resonant characteristics of the diaphragm and housing. Sound pressure level and current consumption are influenced by the input voltage, waveform, duty cycle and mechanical structure.
Many externally driven magnetic transducers use periodic signals such as square waves. The actual waveform, rated voltage and operating frequency must follow the individual product specifications.
Magnetic transducers and active magnetic buzzers both use electromagnetic force to generate sound, but their internal circuit structures and driving requirements are different.
A magnetic transducer generally requires an external periodic driving signal. An active magnetic buzzer contains an internal oscillator circuit and can generate a preset tone when the specified DC supply voltage is applied.
| Comparison | Magnetic Transducer | Active Magnetic Buzzer |
|---|---|---|
| Internal Oscillator | Normally not included | Integrated oscillator circuit |
| Driving Method | External periodic signal | Specified DC power supply |
| Frequency Control | Controlled by the external signal within operating limits | Generally preset by the internal oscillator |
| External Circuit | Requires a signal generation and driving circuit | Usually requires simpler switching control |
| Electrical Parameters | Drive voltage, current, coil resistance and frequency | DC voltage, current and operating frequency |
| Typical Applications | Programmable alarms and electronic control systems | Fixed-tone alarms and simple audible indicators |
Choose an externally driven magnetic transducer when the electronic system needs to generate and control the driving signal. Select an active magnetic buzzer when a preset sound can meet the application requirements and a simpler external circuit is preferred.
Magnetic and piezoelectric transducers use different physical mechanisms to generate sound. Magnetic transducers rely on electromagnetic force, while piezoelectric transducers use the deformation of a piezoelectric ceramic element under an applied electric field.
| Comparison | Magnetic Transducer | Piezoelectric Transducer |
|---|---|---|
| Operating Principle | Electromagnetic force | Piezoelectric effect |
| Main Components | Coil, magnetic circuit and diaphragm | Piezoelectric ceramic and diaphragm |
| Electrical Load | Electromagnetic coil load | Predominantly capacitive load |
| Current Characteristics | Coil current is an important design parameter | Often suitable for lower-current designs |
| Driving Circuit | External signal matched to coil characteristics | AC or pulse voltage matched to capacitance and rated drive |
| Selection Factors | Voltage, current, coil resistance, frequency and SPL | Voltage, capacitance, frequency and SPL |
Neither technology is universally better. Engineers should compare the actual acoustic output, power consumption, circuit requirements and package dimensions of the selected models under equivalent operating conditions.
MANORSHI offers miniature magnetic transducers with different package dimensions, driving voltages, resonant frequencies and sound pressure levels. The range includes compact 9mm designs, 12mm configurations and larger 16mm magnetic sound components.
The following table summarizes the published specifications of representative models.
| Model | Dimensions | Rated Drive Voltage | Frequency | SPL | Current | Operating Voltage |
|---|---|---|---|---|---|---|
| MSET09A | 9 × 4mm | 1.5Vp-p | 2730 ± 500Hz | ≥85dB @ 10cm | ≤80mA | 1–2Vp-p |
| MSET09B | 9 × 5mm | 3Vp-p | 2730 ± 500Hz | ≥87dB @ 10cm | ≤70mA | 2–4Vp-p |
| MSET09C | 9 × 4mm | 3Vo-p* | 2731 ± 500Hz | ≥85dB @ 10cm | ≤90mA | 2.5–4.2Vp-p |
| MSET10A | 9.6 × 5mm | 5Vo-p* | 2731 ± 500Hz | ≥85dB @ 10cm | ≤80mA | 4–7Vp-p |
| MSET10C | 9.6 × 5mm | 1.5Vp-p | 2730 ± 500Hz | ≥86dB @ 10cm | ≤80mA | 1–2Vp-p |
| MSET12A | 11.8 × 9mm | 5Vp-p | 2000 ± 500Hz | ≥85dB @ 10cm | ≤50mA | 3–7Vp-p |
| MSET12B | 12 × 7.5mm | 1.5Vp-p | 2048 ± 500Hz | ≥70dB @ 10cm | ≤70mA | 1–2Vp-p |
| MSET12C | 12 × 5.4mm | 3Vp-p | 2048 ± 500Hz | ≥75dB @ 10cm | ≤30mA | 1.5–3Vp-p |
| MSET12D | 12 × 8.5mm | 1.5Vp-p | 2400 ± 300Hz | ≥85dB @ 10cm | ≤30mA | 3–5Vp-p |
| MSET16A | 16 × 14mm | 6Vp-p | 2048 ± 500Hz | ≥85dB @ 10cm | ≤40mA | 4–8Vp-p |
*The current category listing uses Vo-p for the rated drive voltage of MSET09C and MSET10A. Please confirm the exact voltage notation and waveform against the corresponding product datasheets before final engineering approval.
Vp-p means peak-to-peak voltage, while Vo-p commonly refers to zero-to-peak voltage. These values should not be treated as interchangeable with DC supply voltage. The driving waveform and voltage measurement method must be confirmed for each model.
The published SPL values in this table are measured at 10cm. Current consumption and acoustic performance depend on the specified driving conditions. Consult the individual datasheet for complete electrical and mechanical specifications.
Get Magnetic Transducer Datasheets
The electrical and acoustic characteristics of a magnetic transducer determine its compatibility with the external driver, power supply and final electronic product. Engineers should evaluate the following parameters before selecting a model.
Rated drive voltage specifies the electrical signal level used to evaluate the transducer's performance. Operating voltage defines the permitted signal range stated in the product specifications.
Externally driven magnetic transducers commonly specify their input voltage in peak-to-peak or zero-to-peak terms. These are AC or periodic signal measurements and should not be confused with the DC supply ratings of active buzzers.
Current consumption indicates the electrical current required by the electromagnetic coil under specified driving conditions. It is an important parameter when selecting a driver IC, transistor, MOSFET or power supply.
Current should be evaluated at the specified rated voltage, frequency and waveform. Maximum current values should be used when checking the current capability of the driving circuit.
Coil resistance is the DC resistance of the electromagnetic winding. Impedance describes the electrical opposition to an alternating signal and varies with frequency and circuit characteristics.
These parameters help engineers evaluate electrical loading, current requirements and compatibility with the external signal generator. Please request the detailed datasheet when coil resistance or impedance is required for circuit calculations.
Resonant frequency is the frequency at which the mechanical structure produces a strong acoustic response. It is influenced by the diaphragm, magnetic circuit and housing design.
MANORSHI magnetic transducer models include resonant frequencies around 2000Hz, 2048Hz, 2400Hz, 2730Hz and 2731Hz. Select the appropriate model according to the required audible tone and driving signal.
Sound pressure level measures the acoustic output of a magnetic transducer and is expressed in decibels (dB). It helps determine whether the component can provide sufficient audible feedback in the intended environment.
When comparing different models, check the test distance, rated drive voltage, frequency and input waveform. The surrounding enclosure and sound outlet design can also affect the acoustic performance of the finished product.
Operating temperature defines the environmental range in which a magnetic transducer is specified to function. Electronic equipment used in outdoor or industrial environments may require different temperature performance from indoor consumer devices.
Confirm the operating and storage temperature ranges of the selected model before finalizing the component specification.
The external dimensions determine the available mounting space and mechanical compatibility. The sound outlet position also influences PCB placement and enclosure design.
Top-sound and side-sound configurations should be selected according to the intended sound radiation direction. Avoid obstructing the acoustic outlet with PCB components, adhesives or enclosure structures.
An externally driven magnetic transducer requires a suitable electrical signal from the host circuit. The signal generator, driver stage and power supply must be matched to the transducer's rated voltage, current and frequency.
Many magnetic transducers operate with an external periodic signal such as a square wave. The signal frequency determines the excitation frequency, while its voltage and duty cycle affect the electrical and acoustic response.
The waveform should be generated according to the individual datasheet. Do not assume that all magnetic transducers use the same frequency, duty cycle or voltage amplitude.
A microcontroller can generate the required timing signal, but its GPIO output may not be able to supply the current required by the electromagnetic coil. An external driver stage may therefore be necessary.
Check the output current capability, signal voltage and switching frequency of the driver IC. Select the circuit according to the maximum current and electrical requirements of the transducer.
Transistors and MOSFETs can be used as external switching devices when the controller cannot directly drive the electromagnetic load. Their voltage, current and switching characteristics must match the selected transducer and power supply.
Because the electromagnetic coil is an inductive load, the circuit designer should also evaluate switching transients and suitable protection measures. The protection arrangement must be compatible with the intended AC or pulse drive waveform.
The driver must provide the correct input voltage and sufficient current under the specified operating conditions. Excessive voltage or current can cause overheating, electrical stress or reduced component reliability.
For battery-powered products, evaluate the transducer's current consumption and activation duty cycle together with the available battery capacity.
The PCB layout should follow the component's terminal configuration and mechanical drawing. The acoustic opening must remain unobstructed after installation in the final enclosure.
For production applications, test the transducer with the actual PCB, driver circuit and enclosure. This helps identify acoustic changes caused by mounting position, enclosure resonance and surrounding materials.
Magnetic transducers are used in electronic equipment requiring externally controlled audible signals, warning sounds and operating notifications. Their electromagnetic structure allows integration into a wide range of compact electronic devices.
Electronic doorbell systems use magnetic transducers to generate audible visitor notifications. External signal control allows the host circuit to determine when the sound is activated and how long it operates.
Security equipment and access control devices use magnetic transducers for audible status indications, access notifications and warning signals. The selected component should meet the required sound pressure level and electrical operating conditions.
Washing machines, refrigerators, microwave ovens and other household appliances use electromagnetic sound components for operation notifications, timer alerts and user feedback.
Electronic control boards use magnetic transducers to provide confirmation sounds, fault notifications and operating alerts. External frequency control allows the host circuit to generate signals according to different operating states.
Communication terminals and electronic devices use compact electromagnetic sound components for audible feedback, incoming notifications and status indication.
Industrial monitoring equipment, control panels and electronic instruments use magnetic transducers for machine status alerts and warning signals. Operating temperature, electrical stability and acoustic output should be evaluated according to the installation environment.
Low-voltage magnetic transducers can be considered for battery-powered devices requiring audible feedback. Engineers should evaluate current consumption, activation duration and driving circuit efficiency when designing for battery operation.
Selecting a magnetic transducer requires matching the electrical signal, acoustic output and mechanical dimensions to the requirements of the final electronic product.
Confirm that your electronic circuit can generate the periodic signal required by an externally driven magnetic transducer. If the design only provides a DC supply and does not include an oscillator, an active magnetic buzzer may be more suitable.
Check the rated drive voltage, operating voltage range and input waveform. Confirm whether the voltage is specified as Vp-p or Vo-p and use the correct measurement method when designing the driver circuit.
Evaluate the current required by the electromagnetic coil and ensure that the power supply and driver can support the load. Request coil resistance and impedance data when detailed circuit calculations are required.
Choose a transducer with a resonant frequency suitable for the intended acoustic signal. Confirm the frequency tolerance and test the actual sound output with the proposed driver.
Select an SPL that meets the audible notification requirements of the application. Compare measurements using the same test distance, driving voltage, frequency and waveform.
Measure the available installation space and check the component dimensions, terminal arrangement and sound outlet position. The selected transducer must fit the PCB and enclosure structure.
Consider operating temperature, humidity, vibration and mechanical installation conditions. Confirm the environmental specifications of the selected model before approving it for production.
Evaluate samples using the actual driving circuit and final enclosure. Check current consumption, sound pressure, frequency response and electrical compatibility before confirming the component for mass production.
MANORSHI supplies magnetic transducers for electronic component distributors, alarm manufacturers, doorbell producers, household appliance manufacturers and industrial electronic equipment developers.
For OEM projects, the appropriate magnetic transducer can be evaluated according to the required package dimensions, driving voltage, frequency, sound pressure level and current consumption.
To help identify a suitable model, please provide the following information:
Required magnetic transducer model or reference sample.
Rated drive voltage and operating voltage range.
Required input waveform and driving frequency.
Maximum current consumption.
Required resonant frequency and frequency tolerance.
Target sound pressure level and test distance.
Package dimensions and mounting requirements.
Top-sound or side-sound configuration.
Operating temperature and environmental conditions.
Sample quantity and estimated annual purchase volume.
Customers can request product datasheets and confirm sample availability for engineering evaluation. Please provide a reference component, electrical drawing or technical specification when a specific acoustic or mechanical configuration is required.
Customization feasibility, minimum order quantity, packaging and production lead time should be confirmed according to the selected model and project requirements.
A magnetic transducer is an electromagnetic sound-generating component that converts electrical signals into audible sound through the vibration of a diaphragm. It generally consists of an electromagnetic coil, magnetic circuit, diaphragm and housing.
An external electrical signal energizes the electromagnetic coil and creates a changing magnetic field. The resulting magnetic force moves the diaphragm repeatedly, producing mechanical vibration and audible sound waves.
A magnetic transducer generally refers to an externally driven electromagnetic sound component that requires a periodic signal from an external circuit. An active magnetic buzzer contains an internal oscillator and can produce a preset tone when supplied with the specified DC voltage. Product naming can vary between manufacturers, so the internal circuit structure should always be checked.
Yes. An externally driven magnetic transducer requires a periodic signal from an external oscillator, microcontroller or driver circuit. The signal frequency and voltage must match the component specifications.
An externally driven magnetic transducer generally requires an alternating or periodic electrical signal rather than continuous DC power. A steady DC voltage alone does not provide the repeated diaphragm movement required for continuous sound. Follow the specified driving method in the product datasheet.
Frequency depends on the component design. MANORSHI's current magnetic transducer range includes models around 2000Hz, 2048Hz, 2400Hz, 2730Hz and 2731Hz. Other frequencies should be confirmed according to available product specifications.
Vp-p means peak-to-peak voltage, which is the difference between the maximum and minimum voltage levels of a signal. It is different from DC voltage and zero-to-peak voltage. Engineers should confirm the voltage notation and waveform before designing the driving circuit.
Vp-p represents peak-to-peak voltage, while Vo-p commonly represents zero-to-peak voltage. For a symmetrical waveform centered around zero, the peak-to-peak value is twice the zero-to-peak value. Always verify the manufacturer's notation and measurement conditions.
Current consumption depends on the coil structure, driving voltage, frequency and waveform. MANORSHI's listed magnetic transducer models have maximum current specifications ranging from 30mA to 90mA. Refer to the individual datasheet for the exact operating conditions.
Coil resistance is the DC resistance of the electromagnetic winding. It helps engineers evaluate the electrical characteristics of the transducer and select a compatible driver circuit. Request the model-specific datasheet for the resistance value.
A magnetic transducer generates sound through electromagnetic force acting on a diaphragm. A piezoelectric transducer uses a ceramic element that deforms under an applied electric field. Their electrical loads, current consumption and driving circuit requirements are different.
SPL means Sound Pressure Level and measures acoustic output in decibels (dB). It should be evaluated together with the test distance, driving voltage, frequency and waveform. MANORSHI's listed magnetic transducer models include SPL specifications from 70dB to 87dB at 10cm.
A top-sound transducer emits sound through an opening on its upper surface, while a side-sound transducer directs sound through an opening on the side of the housing. The selection depends on the PCB layout, enclosure structure and acoustic requirements.
Yes. Magnetic transducers can be used in electronic doorbell systems to generate audible visitor notifications. Select a model with compatible drive voltage, suitable SPL and appropriate installation dimensions.
Check the PCB mounting space, terminal arrangement, rated drive voltage, input waveform, current consumption, resonant frequency and SPL. Test the selected model with the actual driving circuit and final enclosure before approving it for production.
Customers can contact MANORSHI to confirm sample availability for selected magnetic transducer models. Please provide the model number, required quantity and application details for evaluation.
MANORSHI supports OEM and ODM project evaluation for electronic equipment manufacturers and component distributors. Customers can submit their electrical, acoustic and mechanical requirements to identify suitable products and discuss supply arrangements.
Looking for a magnetic transducer manufacturer for your electronic alarm, doorbell, control board or industrial equipment project?
MANORSHI supplies externally driven electromagnetic transducers with different dimensions, drive voltages, resonant frequencies and sound pressure levels for electronic component distributors and OEM manufacturers.
Send us your required driving waveform, voltage, current, frequency, SPL and estimated purchase quantity. Our team can help evaluate suitable models and confirm technical specifications, samples and bulk supply arrangements.
Contact Us
Stay Connected